Analytical chemistry council

METHODS AND OBJECTS OF CHEMICAL ANALYSIS

 

An international journal devoted to all aspects of analytical chemistry

ISSN 2413-6166 (Online), ISSN 1991-0290 (Print)

Kiev University
    Ukr | En
Home Current issue Call for papers ReceivedContact us
cover

Voltammetric Determination of Paracetamol in Pharmaceutical Formulations at Iodine-Coated Polycrystalline Platinum Electrode

Mohammad Amayreh*†, Wafa Hourani‡, Mohammed Khair Hourani§

* Corresponding authors

† Department of Chemistry, Faculty of Science, Al-Balqa Applied University, P.O. Box 19117, Al-Salt, Jordan;
‡ Faculty of Pharmacy, Philadelphia University, Amman, Jordan
§ Department of Chemistry, the University of Jordan, Amman, Jordan
*e-mail: mohammad.amayreh@bau.edu.jo 

Methods Objects Chem. Anal., 2021, 16(2), p. 103-111

https://doi.org/10.17721/moca.2021.103-111

The article is distributed under open access Creative Commons Attribution License CC BY 4.0.

download the article

download the references

Abstract

In this work the modified iodine-coated polycrystalline platinum electrode was used to develope a voltammetric sensor for paracetamol determination in pharmaceutical formulations. The optimized experimental parameters for the determination of paracetamol were using 0.5 M H2SO4 as a supporting electrolyte with a scan rate of 50 mV/s. The anodic peak related to paracetamol oxidation was centered at about +0.60 V. The extended calibration graph was constructed between 1 ppm and 500 ppm. The anodic current showed excellent linearity with R2 = 0.9985. The limit of detection (LOD) and limit of quantitation (LOQ) were 0.046 and 0.139 ppm, respectively, which attests to the sensitivity of the method. The investigation for the effect of potential interferences from the content of tablet matrices indicated a specific selectivity toward paracetamol and the absence of any electrochemical response toward these components. The developed method was successfully applied to analysis paracetamol in three brands of pharmaceutical formulations and the obtained results were in good agreement with the labeled values, besides that, the statistical tests indicated no significant difference at p = 0.05 with a 95 % confidence level.

Keywords: paracetamol, pharmaceutical formulation, voltammetric analysis, iodine-coated platinum electrode, modified platinum electrode

Article language: En


Publisher: Taras Shevchenko National University, Kiev Ukraine

(Analytical chemistry department at Taras Shevchenko National University, 64 Vladimirskaya STR., Kiev, 01601 UKRAINE)
analysis@univ.kiev.ua, www.univ.kiev.ua, +380 (44) 2393444

The journal is indexed in SCOPUS and Web of Science

The journal website: www.moca.net.ua

The articles in this journal are licensed under CC BY 4.0